范立云, 许德, 费红姿, 冯力东, 刘鹏, 周伟. 高速电磁阀电磁力全工况关键参数相关性分析[J]. 农业工程学报, 2015, 31(6): 89-96. DOI: doi:10.3969/j.issn.1002-6819.2015.06.013
    引用本文: 范立云, 许德, 费红姿, 冯力东, 刘鹏, 周伟. 高速电磁阀电磁力全工况关键参数相关性分析[J]. 农业工程学报, 2015, 31(6): 89-96. DOI: doi:10.3969/j.issn.1002-6819.2015.06.013
    Fan Liyun, Xu De, Fei Hongzi, Feng Lidong, Liu Peng, Zhou Wei. Key parameters' correlation analysis on high-speed solenoid valve electromagnetic force under overall operating conditions[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2015, 31(6): 89-96. DOI: doi:10.3969/j.issn.1002-6819.2015.06.013
    Citation: Fan Liyun, Xu De, Fei Hongzi, Feng Lidong, Liu Peng, Zhou Wei. Key parameters' correlation analysis on high-speed solenoid valve electromagnetic force under overall operating conditions[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2015, 31(6): 89-96. DOI: doi:10.3969/j.issn.1002-6819.2015.06.013

    高速电磁阀电磁力全工况关键参数相关性分析

    Key parameters' correlation analysis on high-speed solenoid valve electromagnetic force under overall operating conditions

    • 摘要: 为揭示各参数对高速电磁阀电磁力影响机理及交互作用规律,更有效地进行高速电磁阀参数设计及匹配,首先建立了高速电磁阀有限元数值仿真模型,并通过试验进行了验证。然后结合试验设计与相关性分析思想,基于中心复合试验设计构造了相关性分析的样本点,并利用有限元数值仿真模型得出全工况平面内其响应值,进而获得了相关系数,揭示了全工况平面内电磁阀关键参数本身形成的6个一次因素及其交互作用形成的21个二次因素与电磁力的相关性变化规律。通过相关性分析得出对高速电磁阀电磁力影响显著的一次因素为线圈匝数和衔铁厚度;而二次因素对高速电磁阀电磁力的影响随各工况点的变化复杂,最后研究了线圈匝数与衔铁厚度、衔铁厚度与阻尼孔位置、阻尼孔位置与半径三组显著因素的交互作用原理,为高速电磁阀设计及其电磁力预测提供了理论指导。

       

      Abstract: Abstract: Electronic unit pump (EUP) is a timing controlled fuel injection system used in diesel engines to meet the increasingly strict exhaust emission regulation and improve the economy of the fuel injection. As the key actuator of EUP, high-speed solenoid valve (HSV) determines the fuel injection timing and quantity in EUP. The electromagnetic force of HSV has a significant influence on the response speed and the stability of EUP, which depends greatly on the structure parameters of HSV. However, it is still not comprehensive in the parameter analysis of HSV for most experiments and simulations on the influence rules of single parameter on electromagnetic force or the parameters' influence rules for only one operating condition of HSV. In order to improve effectiveness of HSV's parameters' design and matching, six parameters' influence rules and the parameters' interaction principles on electromagnetic force under overall operating conditions were revealed by correlation analysis. Coils, armature and iron core were the most important parts for generating the electromagnetic force of HSV, and the 3D numerical simulation model of HSV was established in Ansoft Maxwell according to the three parts' actual structures, moreover the accuracy of the model was verified at different working air gaps and driving currents by experiment. Pole length, coil turns, coil location, armature thickness, damping hole location and damping hole radius were selected as the six key parameters of HSV and every parameter's three levels were determined based on their actual values. Due to HSV's working characteristics, the overall operating condition of HSV was dispersed into nine operating condition points to approximate HSV's entire working process. Based on the three levels of each of the six parameters, 47 sample points of the parameters combinations were obtained effectively and accurately by the method of design of experiments (DOE), in which the electromagnetic force was determined as a response variable and the six parameters were selected as experimental factors. Then the electromagnetic force of 423 sample points were got by using the 3D numerical simulation model of HSV to do experiment with the same times. At last, the correlation coefficients of first and second order factors formed by the six key parameters with electromagnetic force were explored under overall operating conditions according to the thought of correlation analysis. By making correlation analysis, the influence rules of the first order factors on electromagnetic force were revealed under overall operating conditions. The rules showed that one factor with significant correlation to electromagnetic force was coil turns, and the correlation decreased with the increase of driving current and increased with the increase of working air gap under different working conditions; the other factor with significant correlation to electromagnetic force was armature thickness, and the correlation increased with the increase of driving current and decreased with the increase of working air gap under different working conditions. The correlations of second order factors to electromagnetic force tended to be very complicate under overall operating conditions. In addition, the interaction principles of coil turns with armature thickness, armature thickness with damping hole location and damping hole location with damping hole radius were revealed. The electromagnetic force of HSV is determined by the complex interactions of characteristic parameters.

       

    /

    返回文章
    返回