    • 摘要: 分析了以单片机为核心组成的自动称量系统中误差产生的原因,提出“断续跟踪”测零、数字滤波,采用“校正”软件对冲量误差进行修正等软件对策。这些软件实际应用于所研制的DSCZ-4自动计量称重机。试验表明,整机工作稳定可靠,在称重为1.5kg情况下,每分钟可称量10次以上,精度可达0.2级。

       

      Abstract: The reasons producing errors in the autoweighting system with a kernel of microcontroller were analyzed. Some measures for correcting the errors, such as zero test of continuous tracing, data filter, and software countermeasures were investigated and adopted. The software correcting was utilized in a DSCZ-4 Autoweighting. The test results showed that the total system has a realizable and stable operation. In the condition of weighting 1500 g it may weigh over 12 times per minute and its precision is up to 0.2 grade.

       

    /