匡亮, 施珮, 季云峰, 平震宇, 陈北京. 改进型支持度函数的WSN水质监测数据融合方法[J]. 农业工程学报, 2020, 36(16): 192-200. DOI: 10.11975/j.issn.1002-6819.2020.16.024
    引用本文: 匡亮, 施珮, 季云峰, 平震宇, 陈北京. 改进型支持度函数的WSN水质监测数据融合方法[J]. 农业工程学报, 2020, 36(16): 192-200. DOI: 10.11975/j.issn.1002-6819.2020.16.024
    Kuang Liang, Shi Pei, Ji Yunfeng, Ping Zhenyu, Chen Beijing. Data fusion method for water quality monitoring using WSN based on improved support function[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2020, 36(16): 192-200. DOI: 10.11975/j.issn.1002-6819.2020.16.024
    Citation: Kuang Liang, Shi Pei, Ji Yunfeng, Ping Zhenyu, Chen Beijing. Data fusion method for water quality monitoring using WSN based on improved support function[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2020, 36(16): 192-200. DOI: 10.11975/j.issn.1002-6819.2020.16.024

    改进型支持度函数的WSN水质监测数据融合方法

    Data fusion method for water quality monitoring using WSN based on improved support function

    • 摘要: 无线传感网络已被广泛应用到水质监测领域中,针对水质监测中对传感器数据高精度的要求,该研究提出一种基于支持度函数的数据融合算法。首先,对各传感器采集的数据进行一致性检测,保证数据的准确性;其次,采用改进的动态时间弯曲距离(Improved Dynamic Time Warping Distance, IDTW)对支持度函数(Support Function, SF)进行优化,实现水质参数时间序列数据间的互支持度计算;最后,通过加权算法完成数据的融合过程,实现错误数据的校正,获得高质量融合数据。该算法在水质监测平台中进行了试验,结果表明,IDTW-SF融合算法的平均绝对误差值为0.279 2%,融合精度较其他对比算法更高,且运行速度较快。IDTW-SF支持度融合算法能够有效弥补现有水质监测系统数据采集准确率低、效率低等缺陷,基于此方法的水质监测系统提高了溶解氧数据准确率,在降低水产养殖风险,提高养殖效率等方面发挥重要作用。

       

      Abstract: Abstract: Wireless sensor network has been widely used in various types of industries, such as water quality detection. Due to all kinds of device faults and transmission faults, there are some outliers during water quality monitoring. In a large monitoring area, the difference between monitoring parameter values exists due to uneven distribution. The monitoring data in a single location is unsuitable to represent the real situation of the whole monitoring area. The data fusion method is used to fuse data in multiple locations. Traditional methods in water quality data fusion have problems of low accuracy and efficiency for limited to poor generalization and complex calculations. In response to requirements of high-precision for sensor data in water quality detection, a novel data fusion method based on a new support function IDTW-SF (Improved Dynamic Time Warping Distance Optimized Support Function) was proposed in this study. Based on the importance of dissolved oxygen in various water quality parameters, it was used as an example to study this research in this study. The purpose of data fusion was for correcting outliers to obtain high-quality data. Firstly, the consistency detection of sensor data improved the quality of the fusion data. With high computing complexity, the traditional Gaussian support function was a defective method in data fusion. The dissolved oxygen content was used for example to study the new data fusion method. An improved dynamic time warping distance IDTW (Improved Dynamic Time Warping Distance) was used to optimize a new support function SF (Support Function), thus calculated the support degree value between water quality time series data. Unlike the Gaussian support function, the SF function obtained mutual support degree of sensors without the exponent calculation. The weighted algorithm was used to complete the data fusion process. Based on Grey correlation analysis, the IDTW-SF combined the dynamic time warping distance. time segment strategy and Mahalanobis distance together. DTW algorithm was applied to replace the Euclidean distance and compute the distance between time series. Time series segmentation strategy was utilized to reduce the computation dimension of the DTW algorithm. To prove the validity of this fusion algorithm, various experiments were carried out on a water quality monitoring platform of aquaculture pond from May 24th, 2017 to May 29th, 2017 in the Freshwater Fisheries Research Center, Jiangsu Province. Different distance measures were applied to optimized the SF function and construct new support functions, such as Cos-SF (Cosine angle optimized SF) and DTW-SF. Meanwhile, existed support functions were realized in this study, such as the G function (Gaussian function). These functions were all used as a comparison. The experimental results showed that the mean absolute error value of the proposed fusion method was 0.279 2%. Compared with DTW-SF, Cos-SF, and SF, the mean absolute error value was reduced by 6.308 7%, 54.214 5%, and 16.306 9%, respectively. And the fusion effect of dissolved oxygen was improved obviously. The run time of the IDTW-SF was just 0.021 7 s. The fusion accuracy of the IDTW-SF support degree function was higher than the counterpart existed functions, and its efficiency was also high. Meanwhile, the residual value of IDTW-SF also had a distinct advantage over the other contrast functions. It was obvious that the combination of the IDTW algorithm and the SF method was reasonable and effective. To summarize, the proposed fusion algorithm in this study fully obtained the correlation of monitoring data and overcame shortcomings of traditional function, thus improved the accuracy and efficiency of fusion results. High fusion accuracy could meet the needs of water quality monitoring in the real world.

       

    /

    返回文章
    返回